Model | UC-3530 | UC-5530 | UC-7530 | UC-A1030 | UC-A1530 | UC-A2530 | UC-A3830 | UC-A6030 | UC-A9530 | UC-A13030 | UC-A20030 | |
Temperature range | 50℃~300℃ | |||||||||||
Controller | PID adaptive controller | |||||||||||
Temp. control optional | Heat-conducting medium outlet temp. control | |||||||||||
Communication protocol | MODBUS RTU protocol RS 485 interface | |||||||||||
Temperature feedback | Heat-conducting medium temperature feedback PT100 | |||||||||||
Temp. accuracy | ±0.5℃ | |||||||||||
Heating power | 3.5kW | 5.5kW | 7.5kW | 10kW | 15kW | 25kW | 38kW | 60kW | 95kW | 130kW | 200kW | |
Cooling capacity | 300℃ | 3.5kW | 5.5kW | 7.5kW | 10kW | 15kW | 25kW | 38kW | 60kW | 95kW | 130kW | 200kW |
200℃ | 3.5kW | 5..5kW | 7.5kW | 10kW | 13kW | 25kW | 38kW | 60kW | 95kW | 130kW | 200kW | |
100℃ | 2.8kW | 4kW | 5kW | 7kW | 12kW | 20kW | 30kW | 48kW | 76kW | 100kW | 160kW | |
65℃ | 1kW | 1.8kW | 2.2kW | 3kW | 5kW | 8.5kW | 12kW | 19kW | 30kW | 40kW | 64kW | |
There are heat exchangers in the system,need to pass water to cool,automatically open the inlet valve as needed | ||||||||||||
Circulation pump | Max35L/min 2BAR | Max35L/min 2BAR | Max50L/min 2BAR | Max50L/min 2.5BAR | Max110L/min 2.5BAR | Max150L/min 2.5BAR | Max200L/min 2.5BAR | Max250L/min 2.5BAR | Max400L/min 2.5BAR | Max400L/min 2.5BAR | Max600L/min3BAR | |
Heater | Flanged pipe electric heater | |||||||||||
Independent temperature limiter | Lneya | |||||||||||
Cooler | Plate heat exchanger/Tube heat exchanger | |||||||||||
Operation panel | Display set temperature and measured temperature,key operation input temperature | |||||||||||
Sefety protection | Self-diagnostics;High pressure switch,overload relay、variety of security features such as thermal protection devices. | |||||||||||
Closed circulation system | The entire system is a fully enclosed system,no oil mist at high temperatures、low temperature does not absorb moisture in the air | |||||||||||
System | The system does not increase the pressure due to high temperature during operation,low temperature automatically replenishes the heat transfer medium. | |||||||||||
Connection size | G3/4 | G3/4 | G1 | G1 | G1 | DN32 PN10 | DN40 PN10 | DN40 PN10 | DN50 PN10 | DN50 PN10 | DN65 PN10 | |
Dimensions cm | 50*85*130 | 50*85*130 | 50*100*175 | 50*100*175 | 70*100*175 | 70*100*175 | 80*120*185 | 100*150*185 | 205*145*205 | 205*145*205 | 275*160*225 | |
Weight kg | 95 | 110 | 120 | 160 | 195 | 265 | 395 | 615 | 1220 | 1400 | 2150 | |
Power | 5KW | 7KW | 9KW | 12kw | 17kw | 28kw | 41kw | 65kw | 101kw | 136kw | 212kw | |
Case material | Cold rolled sheet spray | |||||||||||
Optional | Optional 7-inch color touch screen,recording temperature curve,data export using excel format | |||||||||||
Optional | SUS304 shell | |||||||||||
Optional | Optional external touch screen controller,communication line distance 10m | |||||||||||
Optional | Optional explosion-proof touch screen control system(ExdeIIBT4),communication line distance 10m | |||||||||||
Optional power | 220V 60HZ three phase,440V~480V 60HZ three phase |
we will contact you within 24 hours.