Wuxi Guanya Refrigeration Technology co., ltd
Small Gas Condensing System

Small Gas Condensing System

  • Small Gas Condensing System


  • Product Description
Model HQ-0540 HQ-1040 HQ-2540 HQ-5040 HQ-0575W HQ-1075W HQ-2575W HQ-5075W
Gas flow 5m3/h 10m3/h 25m3/h 50m3/h 5m3/h 10m3/h 25m3/h 50m3/h
Lowest Temp. -40℃ -40℃ -40℃ -40℃ -75℃ -75℃ -75℃ -75℃
Primary Temp. There is no -20℃ -20℃ -20℃ -20℃
Cold box under pressure 0~25bar 0~25bar 0~25bar 0~25bar 0~25bar 0~25bar 0~25bar 0~25bar
Heat Transfer Area 0.8m2 1.5m2 3m2 5m2 0.8m2*2 1.5m2*2 3m2*2 5m2*2
Heat Exchanger Material The standard configuration is copper tube, which can be selected with SUS304\SUS316L.
Low temp. refrigerating capacity 0.8kw 1.5kw 3kw 5kw 0.8kw 1.5kw 3kw 5kw
Cooling way Air cooling Water cooled
Air inlet orifice M16*1 M24*1.5 M38*1.5 DN50 M16*1 M24*1.5 M38*1.5 DN50 PN25
Recovery tank 2L 3L 10L 15L 2L 3L 10L 15L
Discharge orifice M16*1 M24*1.5 M24*1.5 M24*1.5 M16*1 M24*1.5 M24*1.5 M24*1.5
Control system Siemens S7 series PLC and module.
Display-record 7 inch color touch screen, record curve temperature and alarm.
The compressor The French taikang/Emerson valley wheel/Italy is a compressor.
The power supply 220V 50HZ 220V 50HZ 380V 50HZ 380V 50HZ 220V 50HZ 220V 50HZ 380V 50HZ 380V 50HZ
1.2KW 1.8KW 3.5KW 6.6KW 2KW 2.5KW 6KW 10KW
Related Products
  • SLJ -110℃~-150℃

    SLJ -110℃~-150℃

    January 11, 2018Temperature ranges from - 5 ~ - 150 ℃, can meet different temperature; Adopt environmental protection refrigerants; Famous brand semi-closed piston compressor, semi-closed bipolar piston compressor, semi-hermetic screw compressor, main brand are BOCK.view
  • Single Fluid Heat Transfer System SR

    Single Fluid Heat Transfer System SR

    April 10, 2018Working temperature range from -25℃to 200℃, other temperature range need to set to the widest temperature range(-50℃to 250℃) Centralized control of 2~20 reactors, each reactor's and jacket temperature can be set independently. One system control multipleview
  • Reactor Temperature System ZLF

    Reactor Temperature System ZLF

    April 10, 2018A set of cooling heat exchanger, heat exchanger, through proportional adjusting valve control cold heat into the heat exchanger, then through the uniform medium input to the reactor jacketed to do heat exchange and temp. Control, system has inside expansiview
Leave a Message Email Us

we will contact you within 24 hours.

products
Contact US
Tel: + 86 18751545184
E-mail: sales@cnzlj.com
Add: No.203, Hongyun Road, Hongshan Street, Optoelectronics Park, Xinwu District, Wuxi City, Jiangsu Province, China